Version these GPU settings before your second region: a control-plane contract for MIG, time-slicing and vLLM

Before a second GPU region is repeatable, version the GPU Operator values, MIG strategy, time-slicing config, node labels, image digests and vLLM parallelism defaults as control-plane facts, and keep node-scoped and workload-scoped settings in separate layers.

Atom XII ·

A packed auditorium during a technology keynote

The short answer

Version, in one place, the settings that define what a GPU is in every region: GPU Operator chart version and values, MIG strategy, time-slicing configuration, node labels, the driver operating-system constraint, NFD ownership, container image digests, and vLLM parallelism defaults. Keep node-scoped facts such as operating system and labels, and workload requests such as tensor_parallel_size, in their own layers. This three-layer split is a proposal by Atom XII; the mechanisms below come from NVIDIA and vLLM documentation.

What MIG and time-slicing actually provide

NVIDIA's Multi-Instance GPU User Guide describes partitioning supported NVIDIA GPUs into multiple isolated instances, each with dedicated compute and memory resources. The GPU Operator's time-slicing documentation describes the other sharing mode: oversubscription, where workloads scheduled on oversubscribed GPUs interleave with one another. Unlike MIG, there is no memory or fault isolation between time-sliced replicas. The documentation also notes that a request for more than one time-sliced GPU does not guarantee a proportional amount of GPU compute, that each pod can run an unlimited number of processes on the underlying GPU, and that the GPU provides an equal share of time to all processes across all pods. Time-slicing is also the sharing option for older GPUs that do not support MIG, and MIG and time-slicing can be combined to provide shared access to MIG instances. MIG support was added to Kubernetes in 2020.

Cluster-wide defaults versus node-specific overrides

The GPU Operator documentation states that a time-slicing configuration can be applied as a cluster-wide default, applied node-specifically, or combined: a cluster-wide default plus node labels that give certain nodes a node-specific configuration. For example, a configuration can target nodes with Tesla T4 GPUs only. After time-slicing is configured, the Operator applies labels such as nvidia.com/gpu.replicas = 8 and modifies the product label to carry a -SHARED suffix, for example nvidia.com/gpu.product = A100-SXM4-40GB-SHARED on a DGX A100. These labels let a node selector request time-sliced access or exclusive access in the same way it selects a GPU model. A reasoned inference from this mechanism: because replica counts and shared status are encoded in labels that schedulers act on, a multi-region control plane should distinguish global defaults from node overrides and verify the rendered labels after deployment rather than trust the intended configuration.

What the GPU Operator installation fixes in place

The GPU Operator installation page, at patch release v26.7.3, states that a default installation deploys the NVIDIA GPU driver, NVIDIA Container Toolkit, NVIDIA Device Plugin, DCGM Exporter, and MIG Manager as pods on every GPU worker node. Its prerequisites are the items a region template must pin. You need the kubectl and helm CLIs on a client machine. If you use ClusterPolicy for driver configuration, all worker nodes or node groups running GPU workloads must run the same operating system version to use the NVIDIA GPU Driver container; pre-installing the driver on the nodes instead allows different operating systems. Nodes need a container engine such as CRI-O or containerd. If the cluster uses Pod Security Admission, the operator namespace gets the enforcement label pod-security.kubernetes.io/enforce=privileged. Node Feature Discovery is a dependency on each node; the Operator deploys NFD master and worker by default, and you must disable that deployment if NFD already runs in the cluster, which you can check by looking for a feature.node.kubernetes.io label on nodes. The chart installs either as an OCI artifact, verified with Cosign against the NVIDIA public key, or from the classic Helm repository, in both cases with helm install, the gpu-operator namespace, and a pinned chart version.

What vLLM fixes per model

The vLLM parallelism documentation gives the serving topology rules. If the model fits on a single GPU, distributed inference is probably unnecessary. If it fits on one node with multiple GPUs, use tensor parallelism, for example tensor_parallel_size=4 on a 4-GPU node. If it does not fit on one node, combine the two: set tensor_parallel_size to the number of GPUs per node and pipeline_parallel_size to the number of nodes, for example tensor_parallel_size=8 and pipeline_parallel_size=2 on two 8-GPU nodes. For an uneven GPU split on a single node, set tensor_parallel_size=1 and pipeline_parallel_size to the number of GPUs. For GPUs without NVLINK interconnect, such as L40S, the documentation says pipeline parallelism can give higher throughput and lower communication overhead than tensor parallelism. Multi-node deployment requires every node to provide an identical execution environment, including the model path and Python packages, and the documentation recommends container images to keep environments consistent and hide host heterogeneity. The startup log's GPU KV cache size and maximum concurrency lines give a capacity check against your throughput requirements.

A proposed three-layer inventory

The following classification is a proposal, not a documented result. Layer one, control-plane versioned defaults: GPU Operator chart version and rendered values, MIG strategy, the time-slicing configuration, container image digests, and vLLM parallelism defaults per served model. Layer two, node-scoped settings: operating system version, NFD ownership, and the rendered node labels. Layer three, workload-scoped requests: GPU resource requests, tensor_parallel_size and pipeline_parallel_size, and node selectors that pick time-sliced or exclusive GPUs. Treat MIG profiles and time-slicing replica counts as tenant-capability declarations reviewed together with the serving topology, not as ad hoc node settings.

A proposed region-render check and ownership

Also a proposal: before a new region is admitted, render and review five artifacts as a set: the GPU Operator values, the time-slicing config map, the node labels, the image digests, and the vLLM launch arguments. Suggested ownership: the platform owner owns layer one and the render check; the node or region owner owns layer two and confirms the OS and NFD facts; the serving owner owns layer three and signs off the parallelism settings against the model's memory requirements.

The observability gap to close

The GPU Operator documentation states two limits: DCGM-Exporter does not support associating metrics to containers when GPU time-slicing is enabled with the NVIDIA Kubernetes Device Plugin, and the Operator does not monitor changes to a time-slicing config map. A reasoned inference: a control plane that versions the configuration but never verifies that a changed config map was reloaded, or that per-tenant metrics remain attributable, has a gap. A proposed operating step: after any time-slicing change, confirm the reload took effect and check what your metrics pipeline can still attribute per tenant.

Conditions that change the recommendation

Several documented conditions alter the defaults above. Pre-installing the NVIDIA driver removes the single-operating-system constraint. An existing NFD deployment means the Operator's NFD must be disabled at install. GPUs without MIG support leave time-slicing as the only sharing mode, with its documented lack of isolation. GPUs without NVLINK favor pipeline parallelism. A model that fits on one GPU needs no distributed inference at all. Quota systems, billing, network policy and tenant identity are not covered by these sources and need separate diligence.

Sources

  1. NVIDIA Multi-Instance GPU User Guide
  2. Time-Slicing GPUs in Kubernetes - NVIDIA GPU Operator
  3. Installing the NVIDIA GPU Operator
  4. Parallelism and Scaling - vLLM documentation